Effects of the Detector-Collimator on the Gamma-Ray Response Function for a NaI(Tl) Detector in a Constant Time of Counts
This study describes the effects of the detector-collimator on the gamma-ray response function for NaI(Tl) detectors with 2 x2 , 3 x3 and 5 x5 dimensions. In present study we have used five different detector-collimators and three gamma ray...
Peak shifted properties of the low background NaI(Tl) detectors: An experimental study of response function behavior in different temperature and acquisition time
Due to the necessity of using low background NaI detector in sensitive and accurate measurements, study on the response function variations in different conditions is very important. These types of detectors have different ...
Proper shielding for NaI (Tl) detectors in combined neutron-g fields using MCNP
The importance of reducing the activation of NaI(Tl) detectors when used to detect g-rays in the presence of an intense neutron environment is discussed. Monte-Carlo calculations are used to design proper shielding for these NaI(Tl) detectors...
Evaluation the nonlinear response function of a 3*3 in NaI scintillation detector for PGNAA applications
a suitable neutron shield for NaI detector in order to prevent the activation of NaI (Tl) and a proper g-shield to attenuate the high-rate 4.438MeV g-ray, 241Am–Be g-ray component....
Response Function of a 3×3 in. NaI Scintillation Detector in the range of 0.081 to 4.438 MeV
Response functions of a 3×3 in. NaI detector, which is mainly used in PGNAA
applications, have been calculated by using MCNP-4C code. Calculated results are compared
with measured data by using standard γ-ray ...
The Effect of Detector Dimensions on the NaI (Tl) Detector Response Function
The well-known MCNP code was used to simulate the NaI(Tl) Detector Response Function (DRF) with 2x2, 3x3 and 5x5 crystal dimensions for gamma rays from 241Am, 137Cs and 60Co sources. Then a code named RNAIGA has been slightly written by us which...
IMPROVING THE PERFORMANCE OF 241Am-Be FOR PGNAA APPLICATIONS USING A PROPER SHIELDING FOR NEUTRON SOURCE AND THE NaI DETECTOR
The gamma ray spectrum resolution from a 241Am–Be source-based prompt gamma ray activation analysis set-up has been observed to increase in the energy region of interest with enclosing the NaI detector in a proper neutron ...
The measurements of thermal neutron flux distribution in a paraffin phantom
was used. Thermal neutron flux determination in
paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger–
Muller counter and NaI(Tl)) was the aim of this project. The relative differences...