Peak shifted properties of the low background NaI(Tl) detectors: An experimental study of response function behavior in different temperature and acquisition time
نویسنده:
, , , , ,سال
: 2016
چکیده: Due to the necessity of using low background NaI detector in sensitive and accurate measurements, study on the response function variations in different conditions is very important. These types of detectors have different responses in various measurement conditions, including time, temperature and high voltage. In this study, the response function of 76 B 76 LB NaI (SCIONIX) in different conditions is discussed. According to the channel shifting in these detectors and its direct effect on degrading the resolution, the most convenient measurement condition for these detectors, is proposed. Finally, it is recommended that before long-time measurements a “waiting time” is needed to avoid the channel shifting effects.
کلیدواژه(گان): Channel shifting,Low background NaI(Tl),Response function
کالکشن
:
-
آمار بازدید
Peak shifted properties of the low background NaI(Tl) detectors: An experimental study of response function behavior in different temperature and acquisition time
Show full item record
contributor author | یاسمن رضایی مقدم | en |
contributor author | سیدهاشم میری حکیم آباد | en |
contributor author | لاله رفعت متولی | en |
contributor author | Yasaman Rezaei Moghaddam | fa |
contributor author | Seyyed Hashem Miri Hakimabad | fa |
contributor author | Laleh Rafat Motavali | fa |
date accessioned | 2020-06-06T13:31:52Z | |
date available | 2020-06-06T13:31:52Z | |
date issued | 2016 | |
identifier uri | http://libsearch.um.ac.ir:80/fum/handle/fum/3358689 | |
description abstract | Due to the necessity of using low background NaI detector in sensitive and accurate measurements, study on the response function variations in different conditions is very important. These types of detectors have different responses in various measurement conditions, including time, temperature and high voltage. In this study, the response function of 76 B 76 LB NaI (SCIONIX) in different conditions is discussed. According to the channel shifting in these detectors and its direct effect on degrading the resolution, the most convenient measurement condition for these detectors, is proposed. Finally, it is recommended that before long-time measurements a “waiting time” is needed to avoid the channel shifting effects. | en |
language | English | |
title | Peak shifted properties of the low background NaI(Tl) detectors: An experimental study of response function behavior in different temperature and acquisition time | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | Channel shifting | en |
subject keywords | Low background NaI(Tl) | en |
subject keywords | Response function | en |
journal title | Radiation Physics and Chemistry | fa |
pages | 62-67 | |
journal volume | 126 | |
journal issue | 1 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1059239.html | |
identifier articleid | 1059239 |