Designing and Optimization of Neutron Dosimeter

Author:
پریسا اخلاقی
,
عطیه ابراهیمی خانکوک
,
سیدهاشم میری حکیم آباد
,
لاله رفعت متولی
,
نجمه محمدی
,
Parisa Akhlaghi
,
Atiyeh Ebrahimi Khankook
,
Seyyed Hashem Miri Hakimabad
,
Laleh Rafat Motavali
,
najmeh mohammadi
Year
: 2011
Abstract: Low energy neutrons produce harmful biological effect in human body, although applying a neutron dosimeter can’t determine the absolute received dose but it can be useful in warning at infected situation. Designing a device to approximate the received dose is the purpose of this research. 3He used as a sphere thermal neutron detector with a radius of 5 cm encircled by a 10 cm radius of paraffin sphere.

In order to estimate the received dose, after measuring the detector counts, the paraffin sphere replaced with ICRU one which contains soft tissues and dose equivalent determined as a desired output.

The quantity that is measurable for neutron dosimeter is counts, so the necessity of finding an appropriate relation between counts and equivalent dose is obvious. Results on the energies below 1 MeV demonstrated the similarity of changing process of these two quantities, so they could be related to each other with an adequate factor.

To find the best fit different factors considered and the smallest χ2 (goodness of fit) was 162533 due to a factor of about 7.5e8. To improve χ2 two covers of cadmium and gadolinium, separately, put around the detector and χ2 resulted from the new simulations were 32568 for cadmium cover and 4238 for gadolinium due to factors of 136388900 and 1.75e7, respectively. Then, gadolinium cover fits the curves of counts and equivalent dose in best way, so applying a simple detector lead us to estimate whole body equivalent dose.
URI: https://libsearch.um.ac.ir:443/fum/handle/fum/3380781
Keyword(s): Neutron dosimeter,Counts,Equivalent dose,χ2
Collections :
  • ProfDoc
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Designing and Optimization of Neutron Dosimeter

Show full item record

contributor authorپریسا اخلاقیen
contributor authorعطیه ابراهیمی خانکوکen
contributor authorسیدهاشم میری حکیم آبادen
contributor authorلاله رفعت متولیen
contributor authorنجمه محمدیen
contributor authorParisa Akhlaghifa
contributor authorAtiyeh Ebrahimi Khankookfa
contributor authorSeyyed Hashem Miri Hakimabadfa
contributor authorLaleh Rafat Motavalifa
contributor authornajmeh mohammadifa
date accessioned2020-06-06T14:03:42Z
date available2020-06-06T14:03:42Z
date copyright11/2/2011
date issued2011
identifier urihttps://libsearch.um.ac.ir:443/fum/handle/fum/3380781?locale-attribute=en
description abstractLow energy neutrons produce harmful biological effect in human body, although applying a neutron dosimeter can’t determine the absolute received dose but it can be useful in warning at infected situation. Designing a device to approximate the received dose is the purpose of this research. 3He used as a sphere thermal neutron detector with a radius of 5 cm encircled by a 10 cm radius of paraffin sphere.

In order to estimate the received dose, after measuring the detector counts, the paraffin sphere replaced with ICRU one which contains soft tissues and dose equivalent determined as a desired output.

The quantity that is measurable for neutron dosimeter is counts, so the necessity of finding an appropriate relation between counts and equivalent dose is obvious. Results on the energies below 1 MeV demonstrated the similarity of changing process of these two quantities, so they could be related to each other with an adequate factor.

To find the best fit different factors considered and the smallest χ2 (goodness of fit) was 162533 due to a factor of about 7.5e8. To improve χ2 two covers of cadmium and gadolinium, separately, put around the detector and χ2 resulted from the new simulations were 32568 for cadmium cover and 4238 for gadolinium due to factors of 136388900 and 1.75e7, respectively. Then, gadolinium cover fits the curves of counts and equivalent dose in best way, so applying a simple detector lead us to estimate whole body equivalent dose.
en
languageEnglish
titleDesigning and Optimization of Neutron Dosimeteren
typeConference Paper
contenttypeExternal Fulltext
subject keywordsNeutron dosimeteren
subject keywordsCountsen
subject keywordsEquivalent doseen
subject keywordsχ2en
identifier linkhttps://profdoc.um.ac.ir/paper-abstract-1024696.html
conference titleThe 1st MEFOMP International Conference of Medical Physicsen
conference locationشیرازfa
identifier articleid1024696