Show simple item record

contributor authorغلامحسین رونقیen
contributor authorمهرنوش قنبریen
contributor authorنرجس اشرفen
contributor authorGlamhossein Ronagifa
contributor authormehrnoush ghanbarifa
contributor authorNarjes Ashraffa
date accessioned2020-06-06T14:18:48Z
date available2020-06-06T14:18:48Z
date copyright8/26/2015
date issued2015
identifier urihttps://libsearch.um.ac.ir:443/fum/handle/fum/3391318?locale-attribute=fa&show=full
description abstractUranium is a radioactive metal that exists ubiquitously in the Environment [1]. Since uranium is one of the main sources in nuclear energy generation and enriched uranium is a major component in nuclear weapons, human beings have a high chance of being exposed to uranium, which can cause severe adverse effects to human health [2,3]. large amount of uranium in drinking water may lead to harmful biological effects in humans. The chemical toxicity caused by natural uranium gives a major risk to the kidneys. For these reasons, detection of uranium is very important.

Potentiometric sensors based on ion-selective electrodes are especially suited for such determination because they offer advantages such as selectivity, sensitivity, good precision, simplicity and low cost. One of the most common classes of sensors is that based on ionophores – organic and inorganic compounds that bind to ions[4].

An uranylcation selective electrode based on kryptofix-22DD (1,10-didecyl-1,10-diaza-18-crown-6) incorporated into a polyvinylchloride (PVC) membrane has been developed. The electrode exhibits a Nernstian slope(30 mv.decade-1) in a wide linear concentration range of 1.0 × 10-1 to 1.0 × 10-4mol l-1. The effects of the pH and possible interfering ions were investigated and the optimized conditions for electrode were evaluated. The sensor is used for the determination of uranium as uranyl ions in real sample. The results are compared with those obtained by independent UV–vis technique.





1\tG. Konstantin, Environmental Monitoring and Assessment,2003, 89, 197.

2 \tE. Craft, A. Abu-Qare, M. Flaherty, M. Garofolo, H. Rincavage, M. Abou-Donia, Journal of Toxicology and Environmental Health B Crit. Rev,2004,7, 297.

3 P. Zhou, B. Gu, Environmental Science and Technology, 2005, 39, 4435.

4R. D. Johnson, L. G. Bachas, Analytical and Bioanalytical Chemistry,2003, 376, 328–341.
en
languageEnglish
titleDesign and construction of ion-selective membrane electrode based on kryptofix-22DD for determination of uranyl ions in environmental samplesen
typeConference Paper
contenttypeExternal Fulltext
subject keywordsuranylcationen
subject keywordsPotentiometryen
subject keywordsEnvironmentalen
identifier linkhttps://profdoc.um.ac.ir/paper-abstract-1049302.html
conference titleهفتمین سمینار شیمی ومحیط زیست ایرانfa
conference locationتهرانfa
identifier articleid1049302


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record