Cu-water Nanofluid Flow and Heat Transfer in a Heat Exchanger Tube Equipped with Cross-Cut Twisted Tape
نویسنده:
, , ,سال
: 2018
چکیده: This paper presents a numerical analysis for Cu-water nanofluid flow through a circular duct inserted with cross-cut twisted tape with alternate axis (CCTA). Three dimensional (RNG) k − ϵ turbulence model is applied to simulate this problem. All simulations are performed for plain tube and nine different CCTA geometries in the range of width ratio (b/w) from 0.7 to 0.9, length ratio (s/w) from 2 to 2.5, Reynolds numbers in the range of 5000 to 15,000 and volume fraction of nanoparticles from 0 to 1.5%. The calculated results indicate that the swirl flow created by CCTA is transferred from the tube core to the near wall regions. This results in higher fluid mixing, which enhances heat transfer and friction factor near the tube wall. The results show that the heat transfer coefficient increases up to 23.20% with increasing the nanoparticle volume fraction from 0% to 1.5%. Finally, it is shown that the thermal performance increases by increasing the volume fraction of nanoparticles inside the duct.
کلیدواژه(گان): Cross-cut twisted tape
Turbulent flow
Thermal performance
کالکشن
:
-
آمار بازدید
Cu-water Nanofluid Flow and Heat Transfer in a Heat Exchanger Tube Equipped with Cross-Cut Twisted Tape
Show full item record
contributor author | مهدی عرفانیان نخچی طوسی | en |
contributor author | جواد ابوالفضلی اصفهانی | en |
contributor author | mahdi erfanian | fa |
contributor author | Javad Abolfazli Esfahani | fa |
date accessioned | 2020-06-06T13:41:30Z | |
date available | 2020-06-06T13:41:30Z | |
date issued | 2018 | |
identifier uri | https://libsearch.um.ac.ir:443/fum/handle/fum/3365214 | |
description abstract | This paper presents a numerical analysis for Cu-water nanofluid flow through a circular duct inserted with cross-cut twisted tape with alternate axis (CCTA). Three dimensional (RNG) k − ϵ turbulence model is applied to simulate this problem. All simulations are performed for plain tube and nine different CCTA geometries in the range of width ratio (b/w) from 0.7 to 0.9, length ratio (s/w) from 2 to 2.5, Reynolds numbers in the range of 5000 to 15,000 and volume fraction of nanoparticles from 0 to 1.5%. The calculated results indicate that the swirl flow created by CCTA is transferred from the tube core to the near wall regions. This results in higher fluid mixing, which enhances heat transfer and friction factor near the tube wall. The results show that the heat transfer coefficient increases up to 23.20% with increasing the nanoparticle volume fraction from 0% to 1.5%. Finally, it is shown that the thermal performance increases by increasing the volume fraction of nanoparticles inside the duct. | en |
language | English | |
title | Cu-water Nanofluid Flow and Heat Transfer in a Heat Exchanger Tube Equipped with Cross-Cut Twisted Tape | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | Cross-cut twisted tape Turbulent flow Thermal performance | en |
journal title | Powder Technology | fa |
pages | 985-994 | |
journal volume | 339 | |
journal issue | 1 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1069852.html | |
identifier articleid | 1069852 |