Digital neutron-gamma discrimination with scintillators: An innovative approach
سال
: 2017
چکیده: In this paper, a digital neutron–gamma discrimination (DNGD) method with an NE213 scintillator has been proposed in which the anode pulse is divided into two different pulses, one representing the amplitude and the other characterizes the DNGD. Then the two pulses are summed up after travelling through delay and mixer circuits to form an input pulse for sampling in analog–to–digital converter (ADC). The discrimination tests have been performed with an 8–bit digital storage oscilloscope (DSO) as ADC and 241Am–Be neutron source, whereas the Fourier method has been used to derive the discrimination characteristic. The results confirm the fast performance and efficiency of proposed method.
کلیدواژه(گان): Neutron-gamma discrimination,Neutron,Gamma,Analog-to-digital convertor,Digital storage oscilloscope,Americium-beryllium neutron source
کالکشن
:
-
آمار بازدید
Digital neutron-gamma discrimination with scintillators: An innovative approach
Show full item record
contributor author | S. Jamili | en |
contributor author | E. Bayat | en |
contributor author | نیما قلعه | en |
contributor author | Nima Ghal-Eh | fa |
date accessioned | 2020-06-06T13:34:42Z | |
date available | 2020-06-06T13:34:42Z | |
date issued | 2017 | |
identifier uri | https://libsearch.um.ac.ir:443/fum/handle/fum/3360582?locale-attribute=fa | |
description abstract | In this paper, a digital neutron–gamma discrimination (DNGD) method with an NE213 scintillator has been proposed in which the anode pulse is divided into two different pulses, one representing the amplitude and the other characterizes the DNGD. Then the two pulses are summed up after travelling through delay and mixer circuits to form an input pulse for sampling in analog–to–digital converter (ADC). The discrimination tests have been performed with an 8–bit digital storage oscilloscope (DSO) as ADC and 241Am–Be neutron source, whereas the Fourier method has been used to derive the discrimination characteristic. The results confirm the fast performance and efficiency of proposed method. | en |
language | English | |
title | Digital neutron-gamma discrimination with scintillators: An innovative approach | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | Neutron-gamma discrimination | en |
subject keywords | Neutron | en |
subject keywords | Gamma | en |
subject keywords | Analog-to-digital convertor | en |
subject keywords | Digital storage oscilloscope | en |
subject keywords | Americium-beryllium neutron source | en |
journal title | Radiation Physics and Chemistry | fa |
pages | 13-15 | |
journal volume | 132 | |
journal issue | 5 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1062566.html | |
identifier articleid | 1062566 |