Show simple item record

contributor authorحانیه غفوریان نصیریen
contributor authorمحمدتقی حامدموسویانen
contributor authorR. Kadkhodaeeen
contributor authorHanieh Ghafourianfa
contributor authorMohammad Taghi Hamed Mosavianfa
date accessioned2020-06-06T13:08:03Z
date available2020-06-06T13:08:03Z
date issued2013
identifier urihttps://libsearch.um.ac.ir:443/fum/handle/fum/3342885?show=full
description abstractHigh intensity ultrasonic standing wave field was established in a horizontal direction and its effect on “gas oil” in “water” emulsion separation rate was studied. Also, effects of four parameters on emulsion instability behavior were investigated: ultrasound irradiation time(5-30 min), emulsion position in ultrasound field(17-37 cm), ultrasound input intensity(20,45 and 75%) and dispersed phase concentration(0.5,2 and 10%). Emulsion light absorbance, droplet diameter and distribution were measured to analyze separation efficiency. The optimum states were 10% oil in water emulsion treated at 17 cm distance from ultrasound source under 30 min irradiation time and 20% sound intensity.en
languageEnglish
titleDemulsification of gas oil-water emulsion via high intensity ultrasonic standing waveen
typeJournal Paper
contenttypeExternal Fulltext
subject keywordsEmulsionen
subject keywordsflocculationen
subject keywordsgas oilen
subject keywordsultrasounden
journal titleJournal of Dispersion Science and Technology,en
journal titleJournal of Dispersion Science and Technologyfa
pages483-489
journal volume34
journal issue4
identifier linkhttps://profdoc.um.ac.ir/paper-abstract-1027866.html
identifier articleid1027866


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record