•  English
    • Persian
    • English
  •   Login
  • Ferdowsi University of Mashhad
  • |
  • Information Center and Central Library
    • Persian
    • English
  • Home
  • Source Types
    • Journal Paper
    • Ebook
    • Conference Paper
    • Standard
    • Protocol
    • Thesis
  • Use Help
Search 
  •   FUM Digital Library
  • Search
  •   FUM Digital Library
  • Search
  • All Fields
  • Title
  • Author
  • Year
  • Publisher
  • Subject
  • Publication Title
  • ISSN
  • DOI
  • ISBN
Advanced Search
JavaScript is disabled for your browser. Some features of this site may not work without it.

Search

Show Advanced FiltersHide Advanced Filters

Filters

Use filters to refine the search results.

Now showing items 1-10 of 11

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    A new single ended fault location algorithm for combined transmission line considering fault clearing transients without using line parameters 

    Type: Journal Paper
    Author : Ismail Niazy; Javad Sadeh
    Year: 2013
    Request PDF

    مکانیابی خطا در سیستمهای انتقال با استفاده از فرکانس تشدید 

    Type: Conference Paper
    Author : اسماعیل نیازی; جواد ساده; سهیل سبزواری; ismail niazi; Javad Sadeh
    Year: 2013
    Abstract:

    در این مقاله روش جدیدی برای مکان یابی خطا در

    سیستمهای انتقال ارائه شده است که بر اساس اندازهگیری فرکانسی که

    در آن پدیدة تشدید رخ میدهد پایهریزی شده است. از آنجا که این

    فرکانس با تغییر موقعیت وقوعِ خطا ...

    Novel Fault Location Algorithm Based on the Matching Between Transient Current Samples and Simulated Waveforms Using PSO 

    Type: Conference Paper
    Author : اسماعیل نیازی; جواد ساده; Ebrahim Niazi; ismail niazi; Javad Sadeh
    Year: 2011
    Abstract:

    Relays installed to protect transmission lines

    have current inputs, which take phase currents

    via CTs. Almost all modern numerical relays

    are equipped with “Fault Recording” function

    to record ...

    بکارگیری گذراهای پس از قطع کلید به منظور تعیین مکان خطا در خطوط انتقال ترکیبی – هوایی / کابلی – با استفاده از تبدیل موجک 

    Type: Conference Paper
    Author : اسماعیل نیازی; جواد ساده; ismail niazi; Javad Sadeh
    Year: 2009
    Abstract:

    بکارگیری گذراهای پس از قطع کلید به منظور تعیین مکان خطا در خطوط انتقال ترکیبی – هوایی / کابلی – با استفاده از تبدیل موجک

    Wavelet-Based One-Terminal Fault Location Algorithm for Aged Cables without Using Cable Parameters Applying Fault Clearing Voltage Transients 

    Type: Conference Paper
    Author : اسماعیل نیازی; جواد ساده; ismail niazi; Javad Sadeh
    Year: 2010
    Abstract:

    This paper presents a novel fault location algorithm,

    which in spite of using only voltage samples taken from one

    terminal, is capable to calculate precise fault location in aged

    power cables without ...

    Fault Location Algorithm for Series Compensated Transmission Lines Using Fault Clearing Transients Independent of Line Parameters 

    Type: Conference Paper
    Author : اسماعیل نیازی; جواد ساده; Ebrahim Niazy; ismail niazi; Javad Sadeh
    Year: 2010
    Abstract:

    This paper presents a novel fault location

    algorithm for series compensated

    transmission lines, which utilizes samples

    taken in just one terminal from voltage

    transients generated by fault ...

    A New Single Ended Fault Location algorithm for Combined Transmission Line Considering Fault Clearing Transients without Using Line Parameters 

    Type: Conference Paper
    Author : اسماعیل نیازی; جواد ساده; Ebrahim Niazy; ismail niazi; Javad Sadeh
    Year: 2010
    Abstract:

    This paper presents a new single ended fault

    location method for underground cable

    combined with overhead line that uses fault

    clearing transients instead of fault-generated

    transients without ...

    The Analysis of Lightning on Urban Railway Fed with Direct Current Overhead Power Supply 

    Type: Conference Paper
    Author : Ebrahim Niazy; جواد ساده; اسماعیل نیازی; Javad Sadeh; ismail niazi
    Year: 2010
    Abstract:

    Lightning is one of the most important causes

    of over voltage disturbances in the DC Light

    Railway Transportation (LRT) system, which,

    its effect is not considered, would cause

    serious problems ...

    A New Single Ended Fault Location algorithm for Combined Transmission Line Considering Fault Clearing Transients without Using Line Parameters 

    Type: Journal Paper
    Author : اسماعیل نیازی; جواد ساده; ismail niazi; Javad Sadeh
    Year: 2013
    Abstract:

    In this paper a new single ended fault location method is proposed for underground cable combined with

    overhead lines. In this algorithm fault clearing high frequency transients are used instead of fault-generated ...

    Participation in Reactive Power Market Considering Generator Aging 

    Type: Journal Paper
    Author : اسماعیل نیازی; Hashem Mortazavi; جعفر عبادی; سهیل سبزواری; ابراهیم نیازی; ismail niazi; Jafar Ebadi; ebrahim niazy
    Year: 2010
    Abstract:

    – As one of the most important ancillary services, reactive power production plays a

    crucial rule in power system operation, reliability and security. Because of the opportunity costs

    in providing reactive ...

    • 1
    • 2

    Author

    ... View More

    Year

    Keywords

    ... View More

    Type

    Language (ISO)

    Content Type

    Publication Title

    • About Us
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    DSpace software copyright © 2019-2022  DuraSpace