Search
نمایش تعداد 1-10 از 22
Construction of novel fluoride potentiometric sensors based on conducting polypyrrole doped with different anions
are comparable with expensive commercial fluoride ion selective sensors due to their fast response and simple, low cost fabrication.
Keywords: Flouride, Polypyrrole, Potentiometry, Sensor
References
(1)\tAyoob, S.; Gupta, A...
Design and construction of ion-selective membrane electrode based on kryptofix-22DD for determination of uranyl ions in environmental samples
Uranium is a radioactive metal that exists ubiquitously in the Environment [1]. Since uranium is one of the main sources in nuclear energy generation and enriched uranium is a major component in nuclear weapons, human ...
A potentiometric membrane sensor based on kryptofix 21 for determination of uranyl ions in environmental samples and optimization by miture design method
Abstract
Uranyl ion exists at trace levels in the environment and can cause severe adverse effects to human health. Therefore, it is desirable to develop analytical methods that can determine the trace uranyl ...
A Novel Disposable All Solid State Sensor for Determination of codine
Codeine is a derivative of morphine and belongs to the poppy alkaloid group of opiates
which can produce euphoria. Codeine is qualified as a drug abuse, while is used as a
local anesthetic in many pharmaceutical ...
A potentiometric membrane sensor based on kryptofix 5 for determination of cobalt ions in environmental samples
The need of selective determination of heavy metal ions has increased immensely during the last few decades due to the growing environmental problems [1].
Among heavy metals, the pollution caused by cobalt is of ...
Construction of a PVC based 15-crown-5 electrochemical sensor for Ag(I) cation
The macrocyclic ligand, 15-crown-5, was used as an ionophore for fabrication of a polyvinyl chloride (PVC) based membrane sensor for Ag(I) cation. For construction of the Ag(I) cation selective electrode, the best response ...
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore
This article describes the fabrication of a novel and selective polyvinylchloride (PVC)
membrane potentiometric sensor for Al3+ cation based on 12-crown-4 (12C4) as an ionophore. The
electrode was prepared ...
A PPy-B15C5 modified lanthanum (III) electrode in acetonitrile and its thermodynamic application
Polypyrrole modified electrode prepared by electropolymerization of pyrrole in the presence of a complexing ligand, benzo-15-crown-5 (B15C5), was prepared and investigated as a La3+- selective electrode in acetonitrile. ...
Novel thallium(I) ion-selective electrodes with poly(vinyl chloride) membranes based on three noncyclic crown-type polyethers as suitable neutral ionophores
Three different recently synthesized noncyclic crown ethers were used in polymeric ion-selective electrodes (ISEs) for thallium(I) sensing. The electrode based on a methyl-2-[2-(2-2- 2-(methoxycarbonyl) phenoxy] ethoxyethoxy) ...
Electrochemical synthesis of Alizarin Red S doped polypyrrole and its applications in designing a novel silver (I) potentiometric and voltammetric sensor
Conducting polymer modified electrodes based on the incorporation of the Alizarin Red S (ARS) into polypyrrole (PPy) film during electropolymerization were used for potentiometric and voltammetric detection of silver (I) ...