Two-Dimensional Displacement Sensor Based on CPW Line Loaded by Defected Ground Structure (DGS) with Two Separated Transmission Zeroes

Author:
مجتبی جودکی
,
M. Rezaee
,
Mojtaba Joodaki
Year
: 2016
Abstract: In this paper, application of a Defected Ground Structure (DGS) in realization of one and two dimensional (1D and 2D) microwave displacement sensors is presented. A CPW line with two slots along the line that generate a Transmission Zero (TZ) in the transmission response is printed on a fixed substrate. A metallic patch is also printed on the bottom face of a movable substrate located on the fixed substrate. By moving the upper substrate, the length of the etched slots on the fixed underneath substrate changes and hence, the TZ shifts proportionally. The displacement can be measured based on the frequency shift of the TZ. The 2D displacement sensor has a similar structure with two additional slots perpendicular to the CPW line on the signal trace. The parallel and perpendicular slots generate two separated TZs in two different frequency bands. The proposed 2D displacement sensor uses the frequency range of 2.8GHz to 4.2GHz to measure the horizontal displacement with the high sensitivity of 0.41GHz/1mm and the frequency range of 5.7GHz to 8.8GHz to measure the vertical displacement with the high sensitivity of 1.2GHz/1mm. In comparison with the previous works, the displacement measurement in each direction is independent of the other one. Furthermore, since TZs show narrow notch-frequency bands with high and fixed rejection levels (high Q-factor resonator), independent of the measured displacement, the measurement error is minimized. Also, the dynamic range of the sensor is wide and almost has no intrinsic geometrical limitation. The 2D sensor is fabricated and tested. The measured results show good agreement with the simulated results.
URI: http://libsearch.um.ac.ir:80/fum/handle/fum/3359621
Keyword(s): CPW line,DGS,microwave sensor,two-dimensional displacement sensor
Collections :
  • ProfDoc
  • Show Full MetaData Hide Full MetaData
  • Statistics

    Two-Dimensional Displacement Sensor Based on CPW Line Loaded by Defected Ground Structure (DGS) with Two Separated Transmission Zeroes

Show full item record

contributor authorمجتبی جودکیen
contributor authorM. Rezaeeen
contributor authorMojtaba Joodakifa
date accessioned2020-06-06T13:33:17Z
date available2020-06-06T13:33:17Z
date issued2016
identifier urihttp://libsearch.um.ac.ir:80/fum/handle/fum/3359621?locale-attribute=en
description abstractIn this paper, application of a Defected Ground Structure (DGS) in realization of one and two dimensional (1D and 2D) microwave displacement sensors is presented. A CPW line with two slots along the line that generate a Transmission Zero (TZ) in the transmission response is printed on a fixed substrate. A metallic patch is also printed on the bottom face of a movable substrate located on the fixed substrate. By moving the upper substrate, the length of the etched slots on the fixed underneath substrate changes and hence, the TZ shifts proportionally. The displacement can be measured based on the frequency shift of the TZ. The 2D displacement sensor has a similar structure with two additional slots perpendicular to the CPW line on the signal trace. The parallel and perpendicular slots generate two separated TZs in two different frequency bands. The proposed 2D displacement sensor uses the frequency range of 2.8GHz to 4.2GHz to measure the horizontal displacement with the high sensitivity of 0.41GHz/1mm and the frequency range of 5.7GHz to 8.8GHz to measure the vertical displacement with the high sensitivity of 1.2GHz/1mm. In comparison with the previous works, the displacement measurement in each direction is independent of the other one. Furthermore, since TZs show narrow notch-frequency bands with high and fixed rejection levels (high Q-factor resonator), independent of the measured displacement, the measurement error is minimized. Also, the dynamic range of the sensor is wide and almost has no intrinsic geometrical limitation. The 2D sensor is fabricated and tested. The measured results show good agreement with the simulated results.en
languageEnglish
titleTwo-Dimensional Displacement Sensor Based on CPW Line Loaded by Defected Ground Structure (DGS) with Two Separated Transmission Zeroesen
typeJournal Paper
contenttypeExternal Fulltext
subject keywordsCPW lineen
subject keywordsDGSen
subject keywordsmicrowave sensoren
subject keywordstwo-dimensional displacement sensoren
journal titleIEEE Sensors Journalfa
pages994-999
journal volume17
journal issue4
identifier linkhttps://profdoc.um.ac.ir/paper-abstract-1060894.html
identifier articleid1060894