Studying the effect of the lung size variation on dosimetry and systematic parameters of FUM-IVNAA facility
نویسنده:
, , , , ,سال
: 2015
چکیده: The aim of this paper was quantifying the uncertainties of dosimetry parameters and systematic factors of an in vivo neutron activation analysis (IVNAA) facility for neutron-irradiated individuals with different lung sizes. A series of statistical phantoms with adjustable lungs were modeled in IVNAA facility using Monte Carlo MCNP code. Obtained results showed that the fluctuation of the organ-absorbed dose and effective dose due to the lung size variation is negligible (less than 3 %). Also, changing the lung size will not significantly affect the systematic parameters of the facility.
کلیدواژه(گان): IVNAA,Lung-absorbed dose,Statistical phantoms,Uniformity,Lung size variation
کالکشن
:
-
آمار بازدید
Studying the effect of the lung size variation on dosimetry and systematic parameters of FUM-IVNAA facility
Show full item record
contributor author | عطیه ابراهیمی خانکوک | en |
contributor author | سیدهاشم میری حکیم آباد | en |
contributor author | لاله رفعت متولی | en |
contributor author | Atiyeh Ebrahimi Khankook | fa |
contributor author | Seyyed Hashem Miri Hakimabad | fa |
contributor author | Laleh Rafat Motavali | fa |
date accessioned | 2020-06-06T13:23:26Z | |
date available | 2020-06-06T13:23:26Z | |
date issued | 2015 | |
identifier uri | http://libsearch.um.ac.ir:80/fum/handle/fum/3352919 | |
description abstract | The aim of this paper was quantifying the uncertainties of dosimetry parameters and systematic factors of an in vivo neutron activation analysis (IVNAA) facility for neutron-irradiated individuals with different lung sizes. A series of statistical phantoms with adjustable lungs were modeled in IVNAA facility using Monte Carlo MCNP code. Obtained results showed that the fluctuation of the organ-absorbed dose and effective dose due to the lung size variation is negligible (less than 3 %). Also, changing the lung size will not significantly affect the systematic parameters of the facility. | en |
language | English | |
title | Studying the effect of the lung size variation on dosimetry and systematic parameters of FUM-IVNAA facility | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | IVNAA | en |
subject keywords | Lung-absorbed dose | en |
subject keywords | Statistical phantoms | en |
subject keywords | Uniformity | en |
subject keywords | Lung size variation | en |
journal title | Journal of Radioanalytical and Nuclear Chemistry | fa |
pages | 2263-2270 | |
journal volume | 303 | |
journal issue | 3 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1047193.html | |
identifier articleid | 1047193 |