Shielding Effectiveness Estimation of a Metallic Enclosure with Aperture Using S-parameter Analysis: Analytic Validation and Experiment
This paper presents an analytic closed form expression for shielding effectiveness (SE) estimation of an enclosure with an aperture. The derived expression, which is based on S-parameter analysis and circuit theory forms ...
Using Aperture Impedance for Shielding Effectiveness Estimation of a Metallic Enclosure With Multiple Apertures on Different Walls Considering Higher Order Modes
In this paper, our previously published analytical method for calculation of shielding effectiveness (SE ) of a metallic enclosure with a centered aperture is extended to generalize the method for a much wider range of ...
Using a network of ports for shielding effectiveness optimization of an enclosure with arbitrary shape apertures
A network of ports will be used to determine the optimized locations and geometries for arbitrary shape apertures on a metallic enclosure. This approach benefits from S‐parameter analysis and circuit theory for the description ...
Shielding Effectiveness Measurement for Extremely Small Dimension Enclosures
In this paper, practical aspects of a newly proposed method based on the aperture impedance for estimation and measurement of the shielding effectiveness (SE) of enclosures will be discussed in more details. A special ...
A fast method in estimating shielding effectiveness for an enclosure with apertures
A new and fast method to determine the shielding effectiveness (SE) of an enclosure with aperture is proposed. This method is based on the Z-parameter analysis combined with a circuit theory to define which configuration ...