چکیده: Electrocardiographic (ECG) parameters and cardiac rhythms have been evaluated and published
in different breeds of beef and dairy cattle but there is limited information regarding these
parameters in healthy sheep. This study is aimed to investigate the ECG parameters in Balouchi
sheep. The ECG parameters including the amplitudes of P, Q, R, S and T waves, duration of P, QRS
and T waves and P-R, Q-T and R-R intervals were evaluated in 44 male and female clinically
healthy Balouchi sheep in standard and augmented limb leads (I, II, III, AVR, AVL, and AVF) and
base-apex lead. The mean heart rate was 89.6 beats/minute which had a significant correlation with
age (r=-0.269, p=0.014). Different configurations of P-wave, QRS complex and T wave were
observed in different ECG leads. It was found that age and gender affects some ECG parameters. In
some leads, rams had significantly higher amplitudes of P, Q, R, S and T waves and longer duration
of PRR interval than ewes. Also in some leads, the amplitudes of P, R and S waves were
significantly higher and the duration of QRS complex was shorter in sheep less than one year old
than sheep with age three years or older. The most common cardiac dysrhythmia observed on the
ECG traces was Sinus arrhythmia. Sheep with this dysrhythmia had a significantly lower heart rate
(p<0.05). Also, it was concluded that the base-apex lead was the most suitable lead for ECG
evaluation in sheep.
in different breeds of beef and dairy cattle but there is limited information regarding these
parameters in healthy sheep. This study is aimed to investigate the ECG parameters in Balouchi
sheep. The ECG parameters including the amplitudes of P, Q, R, S and T waves, duration of P, QRS
and T waves and P-R, Q-T and R-R intervals were evaluated in 44 male and female clinically
healthy Balouchi sheep in standard and augmented limb leads (I, II, III, AVR, AVL, and AVF) and
base-apex lead. The mean heart rate was 89.6 beats/minute which had a significant correlation with
age (r=-0.269, p=0.014). Different configurations of P-wave, QRS complex and T wave were
observed in different ECG leads. It was found that age and gender affects some ECG parameters. In
some leads, rams had significantly higher amplitudes of P, Q, R, S and T waves and longer duration
of PRR interval than ewes. Also in some leads, the amplitudes of P, R and S waves were
significantly higher and the duration of QRS complex was shorter in sheep less than one year old
than sheep with age three years or older. The most common cardiac dysrhythmia observed on the
ECG traces was Sinus arrhythmia. Sheep with this dysrhythmia had a significantly lower heart rate
(p<0.05). Also, it was concluded that the base-apex lead was the most suitable lead for ECG
evaluation in sheep.
کلیدواژه(گان): Arrhythmia,electrocardiogram,Balouchi,sheep
کالکشن
:
-
آمار بازدید
Electrocardiographic parameters in clinically healthy Balouchi sheep
Show full item record
contributor author | تهمینه تاجیک | en |
contributor author | سیدعلیرضا تقوی رضوی زاده | en |
contributor author | محمدرضا اصلانی | en |
contributor author | Javad Tajik | en |
contributor author | Tahmineh Tajik | fa |
contributor author | Syed Ali Reza Taghavi Razavizadeh | fa |
contributor author | Mohammad Reza Aslani | fa |
date accessioned | 2020-06-06T13:31:39Z | |
date available | 2020-06-06T13:31:39Z | |
date issued | 2015 | |
identifier uri | http://libsearch.um.ac.ir:80/fum/handle/fum/3358556 | |
description abstract | Electrocardiographic (ECG) parameters and cardiac rhythms have been evaluated and published in different breeds of beef and dairy cattle but there is limited information regarding these parameters in healthy sheep. This study is aimed to investigate the ECG parameters in Balouchi sheep. The ECG parameters including the amplitudes of P, Q, R, S and T waves, duration of P, QRS and T waves and P-R, Q-T and R-R intervals were evaluated in 44 male and female clinically healthy Balouchi sheep in standard and augmented limb leads (I, II, III, AVR, AVL, and AVF) and base-apex lead. The mean heart rate was 89.6 beats/minute which had a significant correlation with age (r=-0.269, p=0.014). Different configurations of P-wave, QRS complex and T wave were observed in different ECG leads. It was found that age and gender affects some ECG parameters. In some leads, rams had significantly higher amplitudes of P, Q, R, S and T waves and longer duration of PRR interval than ewes. Also in some leads, the amplitudes of P, R and S waves were significantly higher and the duration of QRS complex was shorter in sheep less than one year old than sheep with age three years or older. The most common cardiac dysrhythmia observed on the ECG traces was Sinus arrhythmia. Sheep with this dysrhythmia had a significantly lower heart rate (p<0.05). Also, it was concluded that the base-apex lead was the most suitable lead for ECG evaluation in sheep. | en |
language | English | |
title | Electrocardiographic parameters in clinically healthy Balouchi sheep | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | Arrhythmia | en |
subject keywords | electrocardiogram | en |
subject keywords | Balouchi | en |
subject keywords | sheep | en |
journal title | Iranian Journal of Veterinary Science and Technology | fa |
pages | 84-91 | |
journal volume | 7 | |
journal issue | 2 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1058992.html | |
identifier articleid | 1058992 |