Evaluating the effects of statistical changes on internal dosimetry
نویسنده:
, , , , ,سال
: 2015
چکیده: Currently, internal dosimetry evaluations are performed using reference computational phantoms. here are significant discrepancies in the organ absorbed doses regarding the variations in organ mass. In this study, to investigate the effects of changes in the lung mass on the results of internal dosimetry, 98 similar mathematical phantoms were developed, so that the masses of their lungs changed with a Gaussian distribution. The lung was selected as the source. Doses delivered to the organs/tissues for photons with different energy levels, and also per decay of 131I, were calculated using MCNPX. The results showed that changing the mass of the lung has effects on the dose of the lung, especially for low-energy photons and electrons resulting from the decay of 131I. According to the statistical distribution in terms of the SAF as a function of the lung mass, the average value of organ SAFs and the coefficient of variations were estimated. The uncertainties of the lung SAF due to the lung mass variation can be described by the coefficient of variation (CV), which changed from 9% to 19%. This occurs for photon energy in the range of 10 to 4000 keV. This figure stands at 18% per decay of 131I.
کلیدواژه(گان): statistical phantom,internal dosimetry,Monte Carlo,organ dose
کالکشن
:
-
آمار بازدید
Evaluating the effects of statistical changes on internal dosimetry
Show full item record
contributor author | Z. Sajjadi | en |
contributor author | لاله رفعت متولی | en |
contributor author | سیدهاشم میری حکیم آباد | en |
contributor author | S. Mohammadi | en |
contributor author | Laleh Rafat Motavali | fa |
contributor author | Seyyed Hashem Miri Hakimabad | fa |
date accessioned | 2020-06-06T13:27:38Z | |
date available | 2020-06-06T13:27:38Z | |
date issued | 2015 | |
identifier uri | http://libsearch.um.ac.ir:80/fum/handle/fum/3355752 | |
description abstract | Currently, internal dosimetry evaluations are performed using reference computational phantoms. here are significant discrepancies in the organ absorbed doses regarding the variations in organ mass. In this study, to investigate the effects of changes in the lung mass on the results of internal dosimetry, 98 similar mathematical phantoms were developed, so that the masses of their lungs changed with a Gaussian distribution. The lung was selected as the source. Doses delivered to the organs/tissues for photons with different energy levels, and also per decay of 131I, were calculated using MCNPX. The results showed that changing the mass of the lung has effects on the dose of the lung, especially for low-energy photons and electrons resulting from the decay of 131I. According to the statistical distribution in terms of the SAF as a function of the lung mass, the average value of organ SAFs and the coefficient of variations were estimated. The uncertainties of the lung SAF due to the lung mass variation can be described by the coefficient of variation (CV), which changed from 9% to 19%. This occurs for photon energy in the range of 10 to 4000 keV. This figure stands at 18% per decay of 131I. | en |
language | English | |
title | Evaluating the effects of statistical changes on internal dosimetry | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | statistical phantom | en |
subject keywords | internal dosimetry | en |
subject keywords | Monte Carlo | en |
subject keywords | organ dose | en |
journal title | Radioprotection | fa |
pages | 187-194 | |
journal volume | 50 | |
journal issue | 3 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1053843.html | |
identifier articleid | 1053843 |