Microneedle Copper (II) Selective Electrode based on Polypyrrole Doped with 8-Hydroxyquinoline-5-Sulfonic Acid
نویسنده:
, , , , , , , , ,سال
: 2015
چکیده: In the present research, a microneedle Cu (II) selective electrode based on conducting polypyrrole (PPy) doped with 8-hydroxyquinoline-5-sulfonic acid (8-HQS) is introduced. 8-HQS which has been incorporated into the polypyrrole backbone during electropolymerization acts as an active ionophore for Cu (II) ion recognition. Several relevant factors affecting the sensor performance have been investigated and optimized. The proposed electrode showed a linear response over the concentration range of 1.0 × 10−5 to 1.0 × 10−1 M with a sub-Nernstian slope of 22 ± 1 mV per decade change in Cu (II) concentration. The response time of the electrode was less than 10 s and the proposed electrode revealed good selectivity for Cu (II) over a wide variety of other ions and could be used in the pH range of 4.0–7.0. The electrode was successfully employed as an indicator electrode in potentiometric titration of Cu (II) ion with EDTA and also for direct determination of copper in spiked tap water and fruit juice samples. The proposed electrode presents special features such as simplicity of operation, capability of miniaturization of steel substrate, low cost, simple fabrication and suitability to be used as Cu (II) disposable electrode and for mass production.
کلیدواژه(گان): Microneedle,ion selective electrode,copper,8-hydroxyquinoline sulfonate
کالکشن
:
-
آمار بازدید
Microneedle Copper (II) Selective Electrode based on Polypyrrole Doped with 8-Hydroxyquinoline-5-Sulfonic Acid
Show full item record
contributor author | مجید شریفیان | en |
contributor author | نرجس اشرف | en |
contributor author | محمدحسین ارباب زوار | en |
contributor author | محمود چمساز | en |
contributor author | فهیمه افضلی | en |
contributor author | majid kheiveh | fa |
contributor author | Narjes Ashraf | fa |
contributor author | Mohammad Hossein Arbab Zavar | fa |
contributor author | Mahmod CHamsaz | fa |
contributor author | fahimeh afzali | fa |
date accessioned | 2020-06-06T13:21:48Z | |
date available | 2020-06-06T13:21:48Z | |
date issued | 2015 | |
identifier uri | http://libsearch.um.ac.ir:80/fum/handle/fum/3351811 | |
description abstract | In the present research, a microneedle Cu (II) selective electrode based on conducting polypyrrole (PPy) doped with 8-hydroxyquinoline-5-sulfonic acid (8-HQS) is introduced. 8-HQS which has been incorporated into the polypyrrole backbone during electropolymerization acts as an active ionophore for Cu (II) ion recognition. Several relevant factors affecting the sensor performance have been investigated and optimized. The proposed electrode showed a linear response over the concentration range of 1.0 × 10−5 to 1.0 × 10−1 M with a sub-Nernstian slope of 22 ± 1 mV per decade change in Cu (II) concentration. The response time of the electrode was less than 10 s and the proposed electrode revealed good selectivity for Cu (II) over a wide variety of other ions and could be used in the pH range of 4.0–7.0. The electrode was successfully employed as an indicator electrode in potentiometric titration of Cu (II) ion with EDTA and also for direct determination of copper in spiked tap water and fruit juice samples. The proposed electrode presents special features such as simplicity of operation, capability of miniaturization of steel substrate, low cost, simple fabrication and suitability to be used as Cu (II) disposable electrode and for mass production. | en |
language | English | |
title | Microneedle Copper (II) Selective Electrode based on Polypyrrole Doped with 8-Hydroxyquinoline-5-Sulfonic Acid | en |
type | Journal Paper | |
contenttype | External Fulltext | |
subject keywords | Microneedle | en |
subject keywords | ion selective electrode | en |
subject keywords | copper | en |
subject keywords | 8-hydroxyquinoline sulfonate | en |
journal title | Journal of the Electrochemical Society | fa |
pages | 57-61 | |
journal volume | 162 | |
journal issue | 3 | |
identifier link | https://profdoc.um.ac.ir/paper-abstract-1045134.html | |
identifier articleid | 1045134 |