Neutron-gamma discrimination with UGAB scintillator using zero-crossing method
سال: 2012
خلاصه:
The new-type scintillator, Ultima Gold Alpha–Beta (UGAB), was studied for its neutron–gamma discrimination capability. The figure-of-merit and peak-to-valley values for the neutron–gamma discrimination spectra of UGAB ...
A comparison study on three different radiation detectors used for liquid levelmetry
سال: 2013
خلاصه:
In this paper, three different radiation detectors (BF3 counter, NE213 and BGO scintillators) and an 241Am–Be isotopic neutron–gamma source have been used for a typical liquid levelmetry. The study shows that the use of the Am–Be source together...
Light transport feature for SCINFUL
سال: 2008
خلاصه:
An extended version of the scintillator response function prediction code SCINFUL has been developed by incorporating PHOTRACK, a Monte Carlo light transport code. Comparisons of calculated and experimental results for ...